Labtop Photostability Test Chamber are especially designed to conduct stability and shelf life studies on drug and drugs substances. These Chambers are designed to provide high intensity lighting system to comply with ICH guide lines for photo stability conditions with white fluorescent exposure of 1.2 million LUX hours and ultra violet energy exposure of 200 W hours/sq. meters. LABTOP chambers conform to International Standards such as ICH, WHO Guideline, and USFDA requirements. Printer interface for LUX & UV meter, automatic shut off after specified exposure level.
Cat. No. | LPC β 100P | LPC β 200P | LPC-300P | LPC β 400P | LPC β 600P | LPC β 800P | LPC β 1000P |
LPC-100GP | LPC-200GP | LPC-300GP | LPC-400GP | LPC-600GP | LPC-800GP | LPC-1000GP | |
Volume | 100 Liters | 200 Liters | 300 Liters | 400 Liters | 600 Liters | 800 Liters | 1000 Liters |
Temperature | 20.0 β 60.0 ΒΊC | ||||||
Accuracy | Β± 0.2 Β°C | ||||||
Uniformity | Β±2.0 ΒΊC | ||||||
Humidity | 40-98% RH | ||||||
Accuracy | Β±2 % RH | ||||||
Uniformity | Β±3% RH | ||||||
Control system | PLC | ||||||
No. Of tray | Two | Three | Four | Four | Four | Eight | Eight |
No. of doors | Single | Single | Single | Single | Single | Double | Double |
Power | 1500 W | 1750 W | 1750 W | 1750 W | 2000 W | 2500 W | 3500 W |
Voltage | 230 V AC, 50/60 Hz | ||||||
DIMENSIONS (W X D X H ) IN MM AND WEIGHT (KG) | |||||||
Internal Dim | 435x400x600 | 505x400x1005 | 565x450x1205 | 635x530x1205 | 745x670x1205 | 1120x600x1200 | 1150x670x1300 |
External Dia | 580x845x1275 | 650x880x1680 | 710x935x1885 | 780x1010x1880 | 890x1150x1960 | 1370x1075x1920 | 1400x1145x1920 |
Packing size | 707x972x1478 | 777x1007x1883 | 837x1062x2088 | 907x1137x2083 | 1017x1277x2163 | 1497x1202x2123 | 1527x1272x2123 |
Net Weight | 125 | 150 | 205 | 260 | 285 | 315 | 340 |
Gross Weight | 180 | 230 | 280 | 330 | 355 | 405 | 430 |
Data scanner
Eight/Sixteen Channel programmable temperature and humidity data Scanner to record, store and print the data online and off line with variable print time intervals, suitable for 80 col. Dot matrix printer.
Software
βLABTOP DATALINXβ CFR 21 Part 11 compliance web based communication software for data management. Complete with RS-485 multi dropping to monitor multiple chambers to one software.
Stand by Refrigeration system
Ready to use stand by refrigeration system in case of regular system fails. This includes Compressor, Evaporator, condensers and other accessories.
Standby Humidity system
Ready to use stand by Humidity System in case of regular system fails.
Door Access system
Biometrics door access system with Magnetic door lock for secured door access with PC interface communication
Power Backup
Uninterrupted online power supply for PLC in case of power failure
TraysΒ
Additional tray suitable for above equipment as per your requirementΒ
Mobile alert
Mobile alert via GSM Technology in case of system failure
UV and LUX Meter
Calibrated LUX and UV meters for measuring and controlling light intensity and ultraviolet rays
Documentation
For GMP complaint models LABTOP offers DQ IQ, OQ and PQ validation with documentation, reports, calibration and test
Calibration
The equipment is calibrated with the help of master calibrator, which is certified for its accuracy by Electronics Regional Testing Laboratory (ERTL West) Government of India recognized testing laboratory with traceable reference to National Physical Laboratories (NPL).
Service and Support
The training undertaken by our Channel partners and engineers is of the highest standard in the industry, ensuring that our customers are supported by the highest level of technical expertise and as such can be assured that their equipment will perform to the standards required at all times.
Our wide network of Engineers/Technicians enables us to respond to any technical query, ensuring that our customers receive the maximum benefit from their equipment.
NB: Specifications are subject to change without prior notice.
Copyright @ 2024 Labtop Instruments Pvt . Ltd . All rights reserved.