labtop-logo

Cooling Incubator

Cooling Incubator

Labtop Cooling Incubator are specially designed to conduct life cycle testing, Shelf life studies, general incubation and refrigerated storage. Temperature range adjustable from 5.0ºC to 60.0ºC with Micro controller based temperature controller. Chambers are exclusively used for seed testing, Biological studies etc.

cabinet construction

The cabinet of Labtop Chambers is insulated with high density CFC free Poly Urethane Foam. Interior of the chambers are mirror finish stainless Steel (304 SS, 0.8 mm thick). The exterior is white powder coated (1.0 mm thick) mild steel and the door has magnetic gasket with a keyed door lock. Specially designed solid stainless steel wire mesh trays ensure even temperature distribution and storage inside. GMP models are in total stainless steel (Inside S. S 304 with mirror finish and outside. S.S 304 dull finish and inner S.S316 is also available on request at extra cost ).

refrigeration system

The cooling is effected by CFC free refrigeration system with a condensing unit located inside the chamber. Labtop condensing units are characterised by high-efficiency heat transfer and low power consumption.

safety features

control system

PROGRAMMABLE LOGIC CONTROLLER (PLC) SYSTEM

A programmable logic controller (PLC) is a digital computer used for automation of controlling electromechanical processes, such as control of Temperature, Relative Humidity, Standby systems and event management with less maintenance hence no moving parts.

alert management:

salient features

Technical Specifications
CAT. No. LCI–100 LCI–200 LCI-300 LCI–400 LCI–600 LCI–800 LCI–1000 LCI–1500 LCI–2000
LCI–100G LCI-200G LCI-300G LCI-400G LCI-600G LCI-800G LCI-1000G LCI-1500G LCI-2000G
LCI–100P LCI–200P LCI-300P LCI–400P LCI–600P LCI–800P LCI–1000P LCI–1500P LCI–2000P
LCI–100GP LCI–200GP LCI-300GP LCI–400GP LCI–600GP LCI–800GP LCI–1000GP LCI–1500GP LCI–2000GP
Volume 100 Liters 200 Liters 300 Liters 400 Liters 600 Liters 800 Liters 1000 Liters 1500 Liters 2000 Liters
Temperature Range 5.0 -60.0 ºC
Accuracy  ± 0.5 °C
Uniformity ±1.0 °C
Control system Micro control / PLC
No. Doors Single Single Single Single Single Double Double Double Double
No. Of tray 2 3 4 4 4 8 8 10 10
Power 775 W 775 W 775 W 800 W 1150 W 1500 W 2300 W 2300 W 2300 W
Voltage 230 ACV , 50/60Hz
DIMENSIONS (W X D X H ) IN MM AND WEIGHT (KG)
Internal Dim 435x400x600 505x400x1005 565x450x1205 635x530x1205 745x670x1205 1120x600x1205 1150x670x1300 1300x890x1300 1500x1030x1300
External Dia 580x845x1275 650x880x1680 710x935x1885 780x1010x1880 890x1150x1960 1370x1075x1920 1400x1145x1920 1550x1365x1920 1750x1505x1920
Packing size 707x972x1478 777x1007x1883 837x1062x2088 907x1137x2083 1017x1277x2163 1497x1202x2123 1527x1272x2123 1677x1492x2123 1877x1632x2123
Net Weight 120 145 200 255 280 310 335 360 380
Gross Weight 175 225 275 325 350 400 425 450 480

Note :

P Models are with Programmable logic control (PLC)

G Models are made out of Stainless steel 304 (GMP)

labtop datalinx software

Title 21 CFR Part 11 is the part of Title 21 of the Code of Federal Regulations that establishes the United States Food and Drug Administration (FDA) regulations on electronic records and electronic signatures (ERES). Part 11, as it is commonly called, defines the criteria under which electronic records and electronic signatures are considered trustworthy, reliable, and equivalent to paper records.

OPTIONAL ACCESSORIES

PLC system
Programmable Logic Control with Safety controller, auto changeover of Standby systems & other event managements
With 4.3” Color HMI with touch screen, Ethernet connectivity and security lock for prevention of unauthorized tampering

Data Scanner
Eight/Sixteen Channel programmable temperature Data Scanner for record, store and print the data online and off line with variable print time intervals, suitable for 80 col. Dot matrix printer.

Stand by Refrigeration system
Ready to use stand by refrigeration system if the regular system fails (for 600 litres and above ). This includes Compressor, Evaporator, condensers and other accessories.

PC interface communication
Micro controller based PID controller to record, store and print the set values, process values, Date & time with variable print time intervals with RS-485 communication

Software
LABTOP “DATALINX “ CFR 21 Part 11 compliance windows based communication software for data management. Complete with RS-485 multi dropping to monitor chambers to one software.

Timer
Micro controller based programmable cyclic timer of 999 Hrs for controlling of various conditions

Light bank
Chamber Illumination with LED lights bank for photosynthesis studies

Ultra violet lamp
Chamber illumination with UV-C lamp to sterilize the interior

Mobile alert
Mobile alert via GSM Technology in case of system failure

Door access
Biometric magnetic door access for secured door opening and closing with PC interface communication

Power Backup
Uninterrupted online power supply for PLC in case of power failure

Trays
Additional tray suitable for above equipment as per your requirement

Documentation
GMP complaint models LABTOP offers IQ, OQ, PQ and DQ validation with documentation, reports, calibration and test certificates.

Calibration
The equipment is calibrated with the help of master calibrator, which is certified for its accuracy by Electronics Regional Testing Laboratory (ERTL West) Government of India recognized testing laboratory with traceable reference to National Physical Laboratories (NPL).

Service and Support
The training undertaken by our Channel partners and engineers is of the highest standard in the industry, ensuring that our customers are supported by the highest level of technical expertise and as such can be assured that their equipment will perform to the standards required at all times.

Our wide network of Engineers/Technicians enables us to respond to any technical query, ensuring that our customers receive the maximum benefit from their equipment.

NB: Specifications are subject to change without prior notice.

Leading Manufacturers, Exporters And Marketers Of Cooling Incubator