Freeze Thaw Chambers

Freeze Thaw Chambers

salient features

Labtop Programed Logic controlled (PLC ) Freeze thaw chambersΒ are used for drug excursion testing, concrete and asphalt testing, coating and adhesive testing, outdoor weathering testing and extensively used in packaging and pharmaceutical industries, food and beverage industries , for testing and measuring the resistance of products deterioration caused by repeated cycles ofΒ freezingΒ andΒ thawing. Temperature range adjustable from -20.0Β°C to 60.0 Β°C .

cabinet construction

The cabinet of Labtop Freeze Thaw Chambers are insulated with high density CFC free Poly Urethane Foam. Interior of the chambers are mirror finish stainless Steel (304 SS, 1.0 mm thick). The exterior is white powder coated (1.0 mm thick) mild steel and the door has magnetic gasket with a keyed door lock. Specially designed solid stainless steel wire mesh trays ensure even temperature distribution and storage inside. GMP models are in total stainless steel (Inside S. S 304 with mirror finish and outside. S.S 304 dull finish and inner S.S316 is also available on request at extra cost )

SAFETY FEATURES

PROGRAMMABLE LOGIC CONTROLLER (PLC) SYSTEM

A programmable logic controller (PLC) is a digital computer used for automation of controlling electromechanical processes, such as control of Temperature, Relative Humidity, Standby systems and event management with less maintenance hence no moving parts.

alert management:

salient features

Technical Specifications
CAT. No. LFT –100P LFT – 200P LFT-300P LFT – 400P LFT – 600P LFT – 800P LFT – 1000P
LFT–100GP LFT-200GP LFT-300GP LFT-400GP LFT-600GP LFT-800GP LFT-1000GP
Volume 100 Liters 200 Liters 300 Liters 400 Liters 600 Liters 800 Liters 1000 Liters
Temperature -25 ΒΊC to  70 ΒΊC
Accuracy Β± 0.5 Β°C
Uniformity Β± 1.0 Β°C
Controller system Micro control / PLC
No. Of tray 2 3 4 4 4 8 8
No. of Doors Single Single Single Single Single Double Double
Power 500 W 500 W 500W 500 W 750 W 1000 W 1500 W
Voltage 230 V AC , 50/60 Hz
Dimensions (W x D x H ) in mm and weight (kg)
Internal Dim 435x400x600 505x400x1005 565x450x1205 635x530x1205 745x670x1205 1120x600x1205 1150x670x1300
External Dia 580x845x1275 650x880x1680 710x935x1885 780x1010x1880 890x1150x1960 1370x1075x1920 1400x1145x1920
Packing size 707x972x1478 777x1007x1883 837x1062x2088 907x1137x2083 1017x1277x2163 1497x1202x2123 1527x1272x2123
Net Weight 120 145 200 255 280 310 335
Gross Weight 175 225 275 325 350 400 425

NB :

P- Models are with Programmable logic control (PLC)
G- Models are made out of Stainless steel 304 (GMP)

labtop datalinx software

Title 21 CFR Part 11 is the part of Title 21 of the Code of Federal Regulations that establishes the United States Food and Drug Administration (FDA) regulations on electronic records and electronic signatures (ERES). Part 11, as it is commonly called, defines the criteria under which electronic records and electronic signatures are considered trustworthy, reliable, and equivalent to paper records.

OPTIONAL ACCESSORIES

Data Scanner

Eight/Sixteen Channel programmable temperature Data Scanner for record, store and print the data online and off line with variable print time intervals, suitable for 80 col. Dot matrix printer.

PC interface communication

Micro controller based PID controller to record, store and print the set values, process values, Date & time with variable print time intervals with RS-485 communication.

Power Backup

Uninterrupted online power supply for PLC in case of power failure

Trays

Additional tray suitable for above equipment as per your requirement

Software

β€œLABTOP DATALINX β€œ CFR 21 Part 11 compliance windows based communication software for data management. Complete with RS-485 multi dropping to monitor chambers to one software.

Timer

Micro controller based programmable cyclic timer of 999 Hrs for controlling of various conditions

Light bank

Chamber Illumination with LED Light bank for photosynthesis studies

Ultra violet lamp

Chamber illumination with UV-C lamp to sterilize the interior

Mobile alert

Mobile alert via GSM Technology in case of system failure

Door access

Biometric magnetic door access for secured door opening and closing with PC interface communication

DOCUMENTATION

GMP complaint models LABTOP offers IQ, OQ, PQ and DQ validation with documentation, reports, calibration and test certificates.

CALIBRATION

The equipment is calibrated with the help of master calibrator, which is certified for its accuracy by Electronics Regional Testing Laboratory (ERTL West) Government of India recognized testing laboratory with traceable reference to National Physical Laboratories (NPL).

Service and Support

The training undertaken by our Channel partners and engineers is of the highest standard in the industry, ensuring that our customers are supported by the highest level of technical expertise and as such can be assured that their equipment will perform to the standards required at all times.

Our wide network of Engineers/Technicians enables us to respond to any technical query, ensuring that our customers receive the maximum benefit from their equipment.

NB :Β Specifications are subject to change without prior notice.

Leading Manufacturers, Exporters And Marketers Of Photo Stability Chambers